===== TIMING CAMERA TRANSMITTER TO CONTROL BOX RECEIVER ===== **THIS STEP IS ONLY A FUNCTION OF THE 3G M.I.N.E.™ CAMERA. \\ THE 3G I.C.E.™ CAMERA DOES NOT UTILIZE AN INTERNAL TRANSMITTER.** \\ The 3G M.I.N.E. Camera has an internal transmitter on the circuit board and must be located within 50 meters of the M.I.N.E.™ Gate to operate correctly. Users must manually calibrate the camera transmitter signal to each control box receiver the first time they are paired together. One camera will operate multiple control box receivers to trigger multiple gates simultaneously at a trap enclosure. \\ 1. Move camera selector switch from **OFF** to **SETUP**. \\ |2. Open control box housing and press **(A)** receiver button. \\ The receiver red light will only emit for 10 to 15 seconds. | {{ :wiki:camera:3g:3g-timing-1.png?nolink&300 |}} | |3. Press the camera **(A)** left arrow and release then press \\ the camera **(B)** right arrow and release to send a manual \\ RF signal to the control box. The receiver light should \\ flash three times and shut off if performed correctly. \\ Conduct a test by repeating this step, the latch will activate. | {{ :wiki:camera:3g:3g-timing-2.png?nolink&300 |}} | Repeat these steps on other control box receivers if multiple gates are used at the trap enclosure. Move camera selector switch from **SETUP** to **ON** and send SMS text command ***777#** to test transmitter and receiver calibration and gate operation. \\
If you have any questions, refer to the JAGER PRO™ M.I.N.E. & I.C.E. (3G) Camera Operations Video at the 18 minutes and 41 seconds mark, TIMING CAMERA TRANSMITTER TO CONTROL BOX RECEIVER for more information.
---- ---- {{backlinks>.}}